              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              Low smoke zero halogen flame retardant control cable

              低(di)煙(yan)無滷阻燃(ran)控製電纜(lan).jpg
              • 低(di)煙無滷阻燃(ran)控(kong)製電纜.jpg
              Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 7…

              Description:

              An overview, cables:
              Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
              Second, the production of standard:
              Low smoke zero halogen flame retardant control cable to the enterprise standard and reference to GB9330-88 this product is suitable for use in ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
              Three control cables, low smoke zero halogen flame retardant technology performance:
              The product reference articles IEC227, IEC1034, IEC332 international standard design
              Four control cables, low smoke zero halogen flame retardant performance requirements:
              1, into A bundle of burning A or B, (coking section height) : 2.5 m or less.
              The distance of 2, secondary (without burning) : 50 mm or higher;
              3, smoke degree (minimum light transmittance) 60% or higher;
              4, HCL content acuities were 0.5 mg/g.
              Five, the model name:

              model

              The name of the cable

              KVV

              Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

              KVVP

              Copper low smoke zero halogen polyolefin insulated and sheathed woven block flame-retardant control cable

              KVVP2

              Copper low smoke zero halogen polyolefin insulated and sheathed copper tape screened flame-retardant control cable

              KVV22

              Copper low smoke zero halogen polyolefin insulation and sheath steel tape armoured flame-retardant control cable

              KVVR

              Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

              KVVRP

              Copper low smoke zero halogen polyolefin insulated and sheathed textile block flame-retardant control cable

              KVVP2-22

              Copper low smoke zero halogen polyolefin insulated and sheathed copper belt BingBiGang belt sheathed flame-retardant control cable

              KYJY

              Copper core with cross-linked polyethylene insulation polyolefin sheath low smoke zero halogen flame retardant control cable

              KYJYP

              Cross-linked polyethylene insulating tape armored low smoke zero halogen (B or C) A kind of flame retardant power cable

              KYJYP2

              Communication polyethylene insulated fine steel wire armoured low smoke zero halogen (B or C) A kind of flame retardant power cable

              KYJYP3

              Copper core with cross-linked polyethylene insulation polyolefin sheath aluminum-plastic composite belt shielding low smoke zero halogen flame retardant control cable

              KYJY23

              Copper core with cross-linked polyethylene insulation polyolefin sheath steel tape armoured low smoke zero halogen flame retardant control cable

              KYJYP2/23

              Copper core with cross-linked polyethylene insulation polyolefin sheath copper tape BingBiGang tape armored low smoke zero halogen flame retardant control cable

              KYJYP3/23

              Copper core with cross-linked polyethylene insulation polyolefin sheath with lu: su composite BingBiGang armoring low smoke zero halogen flame retardant control cable

              "WDZ" : it means low smoke zero halogen flame retardant
              Six, cable specifications:

              model

              Conductor nominal section (was)

              0.5

              0.75

              1.0

              1.5

              2.5

              4

              6

              10

              some

              KVV
              KVVP

              -

              2 ~ 61

              2 ~ 14

              2 ~ 10

              KVV2

              -

              4-61

              4 ~ 14

              4 ~ 10

              KVV22 
              KVVP2-22

              -

              7 ~ 61

              4-61

              4 ~ 14

              4 ~ 10

              KVVR

              -

              4-61

              -

              -

              KVVRP

              -

              4-61

              4 ~ 48

              -

              -

              Note: recommend some series for: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 44, 48 and 52 and 61 core.
              Seven, delivery requirements:
              1, into a circle of 100 m, a dish should be greater than 100 m;
              2, according to the supply and demand both sides agreement to allow any length of delivery, the length of the measurement error of plus or minus 0.5%.


              Browse: