<tr id="kljy-1q"><address></address></tr>

          1. <i id="kljy-1q"></i>
              <tbody id="kljy-1q"></tbody>
            1. <address><small id="kljy-1q"></small></address>
              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

              Nozzle flowmeter

              23噴(pen)嘴(zui)流量(liang)計(ji)01.jpg
              23噴嘴(zui)流(liu)量計03.jpg
              • 23噴嘴(zui)流(liu)量(liang)計(ji)01.jpg
              • 23噴嘴(zui)流量(liang)計(ji)03.jpg
              ZW series of LGPNozzle flowmeterHas a long history background, all kinds of test data is complete.Si…

              Description:

              Products overview:

              ZW series of LGPNozzle flowmeterHas a long history background, all kinds of test data is complete.Simple structure, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application.Doesn't need a high degree of standardization, solid flow calibration.Standard orifice has reliable experimental data and improve the international and national standards.In foreign countries and has its inherent in the huge domestic market, users are familiar with, data;Follow the international standard calculation and processing, use agile and convenient;The most widely used in domestic flow measurement is still the differential pressure type flowmeter.

              Nozzle with high temperature and high pressure resistance, impact resistance, long service life, large measuring range and accuracy of measurement, suitable for high power plant high temperature and high pressure steam heat-supply pipeline flow of fluid flow measurement.Standard nozzle design and manufacture according to GB/T2624-93, according to JJG640-94 verification, without real flow calibration.

              Second, the working principle:
              ZW series of LGPThe principle is to use the throttle nozzle flowmeter flow sensor.It adopt special on the basis of the nozzle pressure (pressure) throat way, make the flow sensor not only has the advantages of traditional long neck nozzle, at the same time also have outflow coefficient of stability, repeatability of higher unique advantages.Is a kind of high precision flow sensor.Flow calculation formula:

              Type: - mass flow respectively (㎏ / s) and the volume flow (m3 / s);
              - flow coefficient;
              - expansiveness coefficient;
              -- the throttle hole diameter, m;
              - diameter ratio,
              - pipe diameter, m;
              - the flow volume density, ㎏ / m;
              -- differential pressure, Pa;

              By measuring the pressure difference to measure the size of the fluid flow.This kind of measurement method based on the energy conservation law and the law of flow continuity as a benchmark.Fluid filled with pipes, when they flow through the pipe of the throttle device, a beam will local contraction at the throttling of the throttle device, so that the flow velocity increases, the static pressure is low, so the throttling parts before and after the pressure drop is produced, the pressure difference, the greater the flow of medium flow, on the throttling the greater the pressure difference before and after.
              Applications:
              ZW series of LGPNozzle flow meter is to measure flow differential pressure generator, cooperate with all sorts of differential pressure gauge or differential pressure transmitter to measure all kinds of fluid flow in pipes.Standard nozzle throttling device with differential pressure transmitter, can measure the rate of flow of liquid, steam, gas, widely used in petroleum, chemical, metallurgical, power, light industry and other departments.Measured medium is as follows:

              1, liquid: hot and cold water, chemical liquid, light body oil.
              2, gas, blast furnace gas, coke oven gas, all kinds of single-component multicomponent gas.
              3, superheated steam and saturated steam.
              4, compressed air.
              5, natural gas, the torch gas, liquefied petroleum gas.

              Four, the main features:

              1, the throttle device structure easy to copy, simple, firm, stable and reliable performance, long service life, low price.
              2, nozzle adopt international standards and processing
              3, nozzle application range is wide, all single-phase flow are measured, partially miscible flow can also be applied.
              4, standard throttle device without real flow calibration, putting-in-service proactively.
              5, using imported monocrystalline silicon intelligent differential pressure sensor
              6, high precision, perfect the self-diagnosis function
              7, the intelligent standard nozzle intelligent orifice flowmeter range can be adjusted from the programming.
              8, intelligent standard nozzle can be displayed at the same time the cumulative flow and transient flow, pressure, temperature.
              9, have the functions of online, dynamic full compensation, intelligent orifice plate flowmeter has since diagnosis, set range.

              Five, the technical parameters:

              1, the nominal diameter: 20 mm or less DN 630 mm or less;
              2, nominal pressure: PN acuities were 32 mpa;
              3, working temperature: - 50 ℃ or less t 550 ℃ or less;
              4, Reynolds number range: 0.30 beta 0.44 or less, or less 70000 ReD 107 or less or less;
              0.44 beta 0.8 or less, or less 20000 ReD 107 or less or less;
              5, throat diameter ratio: 0.30 beta 0.80 or less or less;
              6, precision: 0.5, 1.0, 1.5, 2.0;
              7, the reference standard: GB/T2624-2006, JJG640-94;
              8, connection mode: flange, welding.

              Six, orifice plate and nozzle flowmeter are two different types of differential pressure type flowmeter:
              1, the nozzle flow meter
              Advantages: long neck nozzle has a long history, there are a large number of all kinds of test data, the nozzle flow meter has simple structure and firm, no moving parts, stable and reliable long-term use, rich experience in design and manufacture and application, high degree of standardization, can need not to flow calibration.Standard nozzle has reliable experimental data and improve the international and national standards.Authentic measurement data, can be used as a trade settlement measurement table.
              Disadvantages: manufacturing complex, the unit price is higher.
              2, the orifice plate
              Orifice meter advantages: high cost performance.Standard orifice plate has a long history, the international and national standards and verification regulations and a large number of experimental data, without real flow calibration.Authentic measurement data, can be used as a trade settlement measurement table.
              Faults: orifice acute Angle edge wear, dirt and other factors will affect measuring accuracy.Verification cycle short 6 to 12 months.
              Seven, the structure form:
              Nozzle flowmeter by part A, perpendicular to the axis of the entrance surface of circular arc form surface B and C part and shrinkage of the entrance of the cylindrical throat E and protection of the edge of to prevent damage to the groove of F, its take pressure way upstream pressure mouth Angle of using access, downstream take pressure can be set up by the pressure of Angle joint, also can be set up in the far downstream.The total length of the nozzle
              A, when 0.30 beta 2/3 or less or less, the nozzle length = 0.6041 d.
              B, when two-thirds beta 0.80 or less or less, the nozzle length = {0.4041 + (0.75 / beta 0.25 beta 2-0.5225) 0.5} d;
              C, ISA 1932 nozzle upstream face by perpendicular to the axis plane and profile for the two arcs of a circular, cylindrical throat and groove for the identified contraction of the nozzle.ISA1932 nozzle way of selecting pressure Angle only pressure a pick up.
              Eight, notable matters of installation:
              1, can be horizontal, vertical or inclined installation, should guarantee the tube filled with liquid.
              2, the throttle device before and after the straight pipe should be straight, bend without visible to the naked eye, at the same time, should be "round", inner surface should be clean, without potholes and sediment;
              3 and the request of straight section length and throttling device installation should be in conformity with the relevant provisions of the GB/T26224-93.
              4, lead pressure pipeline installation should comply with the standards stipulated by the regulations.

              Nine, scope of application and characteristics:

              Throttling a name

              Apply pipe

              (DN mm)

              Apply to diameter ratioB(d/D)

              Application characteristics

              Uncertainty of outflow coefficientEc%

              Design criteria

              Angle of access standard orifice plate

              Ring chamber type

              50-500

              50-500

              0.2-0.75

              0.2-0.75

              Apply to clean mediumGDUnder the condition of structure is suitable for high temperature and high pressure flow rate measurement

              0.6-0.75%

              ISO5167

              GB/T2624-93

              The clamping ring type

              50-500

              0.2-0.75

              Easy to remove dirt, and can be used to clean fluid flow measurement

              Oblique hole type

              450-1000(3000)

              0.2-0.75

              Flange pressure standard orifice plate

              50-1000

              0.2-0.75

              Easy to remove dirt, and are suitable for all kinds of media

              0.6-0.75%

              ISO5167

              GB/T2624-93

              Span with standard orifice plate

              50-1000

              0.2-0.75

              Angle access standard pressure nozzle

              (ISA1932Nozzle)

              50-500

              0.3-0.8

              Small pressure loss, long life, especially suitable for steam flow measurement

              0.8-1.2%

              ISO5167

              GB/T2624-93

              The length to diameter nozzle

              50-630

              0.2-0.8

              Small pressure loss of long service life,LGPType of length to diameter nozzle components for high parameters of water and steam flow measurement

              2.0%

              ISO5167

              GB/T2624-93

              Classic venturi tube

              Mechanical processing type

              100-800

              0.2-0.8

              The pressure loss is small, straight pipe required less than orifice, nozzle

              1.0%

              ISO5167

              GB/T2624-93

              Soldering iron plate type

              200-1200(2000)

              0.4-0.7

              1.5%

              Venturi nozzle

              65-500

              0.316-0.77

              Same as above

              1.2-1.75%

              ISO5167

              GB/T2624-93

              A quarterRound hole plate

              25-150

              0.245-0.6

              Suitable for low Reynolds number

              2.0-2.5%

              DIN BS

              Conical inlet orifice

              25-250

              0.1-0.316

              Same as above

              2.0%

              BS

              Segmental orifice

              50-1500

              0.32-0.8

              Apply to the smudges, there are air bubbles or containing solid particles flow measurement.

              1.5%

              DIN

              The eccentric orifice plate

              100-1000

              0.46-0.84

              1-2%

              ASME

              Small hole plate

              12.5-40

              0.2-0.75

              Applicable to small pipe flow measurement

              0.75%

              ASME

              Lens type orifice

              12.5-150

              0.2-0.75

              Suitable for high pressure temperature small pipe flow measurement

              0.6-0.75%

              ISO5167ASME

              Ten, classification model parameter table:

              The name of the

              model

              Take pressure way

              Nominal pipe diameter (mm)

              Nominal pressure (MPa)

              Execution standard (structure)

              The standard orifice plate

              LGB

              Pressure Angle joint (annulus)

              50~400

              Less than10

              GB2624 K07

              LGB-Z

              Pressure Angle joint (drilling)

              400~2000

              Less than1.6

              LGB

              Ring chamber (8 slot)

              50~400

              Less than32

              The flow measurement manual

              LGB

              Ring room (no flange welded)

              50~275

              Less than28.22

              The flow measurement manual

              LGB-F

              The flange to take pressure

              50~800

              Less than2.5

              GB2624 K06

              LGB-F

              The flange to take pressure

              50~400

              4.0~40

              GB2624 K06

              LGB-J

              Diameter of pressure

              50~760

              Less than10

              GB2624

              Standard nozzle

              LGP

              Pressure Angle joint (annulus)

              50~400

              Less than10

              GB2624

              The flow measurement manual

              LGP-Z

              Pressure Angle joint (drilling)

              400~500

              Less than1.6

              LGP

              Ring chamber (8 slot)

              50~300

              Less than32

              The flow measurement manual

              LGP

              Ring room (high pressure lens pad)

              15~150

              Less than32

              LGP

              Ring room (no flange welded)

              175~350

              Less than17.36

              DG 0702~0710

              The length to diameter nozzle

              LGC-J

              Diameter of pressure

              50~630

              Less than16

              GB2624

              A quarterRound hole plate

              LGH

              Take pressure Angle joint

              50~260

              Less than10

              GB2624

              The flow measurement manual

              LGH-F

              The flange to take pressure

              50~200

              Less than6.4

              Venturi nozzle

              LGL

              Take pressure Angle joint

              65~500

              Less than2.5

              Venturi tube

              LGW

              Take special pressure

              50~1200

              Less than2.5

              Double venturi tube

              LGW-S

              Take special pressure

              Less than1000

              Less than0.6

              Small diameter orifice

              LGX

              Take pressure Angle joint

              12~40

              Less than6.4

              K07(LanHua)

              LGX-F

              The flange to take pressure

              12~40

              Less than6.4

              The enterprise standard

              High pressure lens gasket

              LGT

              Take pressure Angle joint

              50~150

              Less than32

              The flow measurement manual

              Segmental orifice

              LGQ

              Pressure Angle joint (annulus)

              100~400

              Less than1.6

              LGQ-Z

              Pressure Angle joint (drilling)

              400~1000

              Less than1.6

              LGQ-F

              The flange to take pressure

              100~350

              Less than6.4

              Double orifice

              LGS

              Take pressure Angle joint

              100~400

              Less than6.4

              The eccentric orifice plate

              LGN

              Take pressure Angle joint

              100~1000

              Less than6.4

              Current limit orifice

              LG-XL


              10~300

              Less than6.4

              The enterprise standard

              Conical inlet orifice

              LGR

              Take pressure Angle joint

              25~1000

              Less than10

              GB2624

              The wing wind device

              LJY

              Take special pressure

              Less than1000

              Less than0.6

              The enterprise standard

              Eleven, selection of coding:

              model

              said Ming

              ZW-LG

              The throttle device (wei measurement and control)


              Code name

              According to the structure characteristics of the two basic categories


              B

              The standard orifice plate


              P

              Standard nozzle


              Code name

              Nominal pressure (105Pa)


              2.5

              2.5


              10

              10


              16

              16


              25

              25


              64

              64


              100

              100


              200

              200


              Code name

              CAL(mm)


              15~1200

              15~1200mm


              Code name

              According to its structure form of segmentation


              H

              The standard orifice plate(Ring chamber)


              Y

              The standard orifice plate(The flange)


              K

              The standard orifice plate(drilling)


              I

              ISA 1932The nozzle


              L

              The length to diameter nozzle


              W

              Venturi nozzle


              G

              Classic venturi tube


              S

              Double orifice


              Q

              Segmental orifice


              Z

              Conical inlet orifice


              R

              A quarterRound hole plate


              P

              The eccentric orifice plate


              N

              As a whole(Hidden within)Orifice plate


              X

              Wedge orifice


              T

              Out of place in the above special throttling device


              Code name

              medium


              1

              liquid


              2

              gas


              3

              steam


              4

              High temperature liquid


              Code name

              Compensation in the form of


              N

              Without pressure and temperature compensation


              P

              With pressure compensation output


              T

              With temperature compensation output


              Q

              With compensation output pressure and temperature


              Code name

              Differential pressure transmitter range scope


              0

              Micro differential pressure range


              1

              Low differential pressure range


              2

              The differential pressure range


              3

              Elevation difference pressure range


              Code name

              Whether or not to bring a live show


              W

              The throttle device sensors


              X

              Intelligent throttling device

              13 order, design notes:

              When you place an order, please provide the following conditions in order to help the correct choice of the specifications of the flowmeter and coefficient.

              1, pipe size: diameter x wall thickness (mm);

              2, measuring medium name: medium density (kg/m3);

              3, set the flow range: meter range of upper limit and lower limit (kg/h or m3 / h);

              5, work pressure (Mpa);

              6, work temperature: (° C);

              7, such as wei in my company, please provide together: intelligent flow totalizer.especially pressure range, or pressure transmitter type, range;Temperature range, or models, range temperature transmitter.

              After-sales service commitment:

              1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

              2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

              3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

              4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.


              Browse:
              Return To The Top

              分(fen)亯到:

              VPUsK

                  <tr id="kljy-1q"><address></address></tr>

                    1. <i id="kljy-1q"></i>
                        <tbody id="kljy-1q"></tbody>
                      1. <address><small id="kljy-1q"></small></address>