              Frequency converter special cable

              變(bian)頻(pin)器專(zhuan)用電纜.jpg
              • 變(bian)頻器(qi)專用(yong)電(dian)纜(lan).jpg
              Inverter dedicated cable is fit for ac rated voltage up to and including 0.6/1 kv frequency conversi…

              Description:

              An overview, cables:
              Inverter dedicated cable is fit for ac rated voltage up to and including 0.6/1 kv frequency conversion control system for power supply cable or electrical connections, the product has strong resistance to voltage impact, can withstand variable frequency pulse voltage, cable has good shielding electromagnetic interference, and effectively eliminate the noise of the frequency conversion motor, ensure the system stable operation.Widely used in metallurgy, electric power, petrochemical and other industries.
              Second, the frequency converter special cable standards:
              Q/CLB04-2003 
              Flame retardant fire-resistant characteristic test execution GB12666-90 standard
              Three, frequency converter special cable using features:
              1, ac rated voltage U0 / U 0.6/1 kv.
              The highest working temperature: silicone rubber insulated 180 ℃;
              Fluorine 46 insulation 200 ℃ and 260 ℃.
              PVC insulated 70 ℃;
              Crosslinked polyethylene 90 ℃;
              Minimum ambient temperature: cable when the ambient temperature under installation should not below - 40 ℃;PVC sheathed cable not below 0 ℃.
              2, cable installation temperature under installation should not below 25 ℃.
              Permissive bending radius, cable, cable minimum 10 times of cable diameter
              Four, allow temperature and working voltage:
              1, allows the conductor work continuously the highest temperature of 180 degrees Celsius.Short circuit when the highest temperature of 250 degrees Celsius.
              2, in the transport, storage, handling, radiation and a free bending when working + 5 ℃, or fixed installation - 10 ℃ or higher.
              3, rated voltage: 600/1000 v, ac test voltage 3500 v.
              Five, the frequency converter special cable product features:
              1, low effective capacitance.
              2, has shielding performance.
              3, good fireproof combustion performance, can be used in the dangerous area.
              4, low transmission impedance, contains the cable shielding layer, in order to prevent electromagnetic interference, transfer impedance RX is the shielding effectiveness of induced resistance and capacitance to measure, low transmission impedance can provide good electromagnetic compatibility.
              5, symmetrical three core design, electromagnetic compatibility, better than four core cable better performance.Three weather resistance and heat-resistant resin insulated wire core in aperture place even isometric twisted, forming a real concentric structure
              Six, frequency converter special cable main technical indicators:
              1.The finished cable conductor dc resistance (the prescribed GB3956)
              2.Finished cable insulation resistance (20 ℃) fluorine plastic and silicone rubber insulation shall be not less than 100 m Ω * km.PVC insulated should not be less than 50 M Ω * km.
              3.The finished cable communication through 50 hz3. 5 kv / 5 min is not breakdown voltage test.
              4.Shielding layer transfer impedance
              Cable in 100 MHZ transmission impedance is equal to or less than 100 Ω/m.
              The ideal of the cable shielding inhibition coefficient is equal to or less than 0.7.
              Seven, inverter dedicated cable basic type and name:

              model
              The name of the
              BPGG
              Silicone rubber insulated and sheathed wire braided shielding high-temperature frequency conversion power cable.
              BPGGP2
              Silicone rubber insulated and sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
              BPGGPP2
              Silicone rubber insulated and sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable.
              BPGGP3
              Silicone rubber insulated and sheathed aluminum polyester composite film around the package block high temperature resistant frequency conversion power cable.
              BPGVFP
              Silicone rubber insulated sheathed wire braided shielding high-temperature frequency conversion power cable.
              BPGVFP2
              Silicone rubber insulated sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
              BPGVFPP2
              Silicone rubber insulated sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable.
              BPGVFP3
              Silicone rubber insulating sheath aluminum polyester composite film around the package block high temperature resistant frequency conversion power cable.
              BPFFP
              Fluorine 46 insulated and sheathed wire braided shielding high-temperature frequency conversion power cable.
              BPFFP2
              Fluorine 46 insulated and sheathed copper tape around the package block high temperature resistant frequency conversion power cable.
              BPFFPP2
              Fluorine 46 insulated and sheathed wire braided copper tape around the package block high temperature resistant frequency conversion power cable
              BPFFP3
              46 insulation and sheath of aluminum fluoride polyester composite film around the package block high temperature resistant frequency conversion power cable.
              BPVVP
              PVC insulated and sheathed wire braided shielding frequency conversion power cable.
              BPVVP2
              PVC insulated and sheathed copper tape around the package block frequency conversion power cable.
              BPVVPP2
              PVC insulated and sheathed wire braided copper tape around the package block frequency conversion power cable.
              BPVVP3
              PVC insulated and sheathed aluminum polyester composite film around the package block frequency conversion power cable.
              BPYJVP
              Crosslinked polyethylene insulated PVC sheathed wire braided shielding frequency conversion power cable.
              BPYJVP2
              Cross-linked polyethylene insulated PVC sheathed copper tape around the package block frequency conversion power cable.
              BPYJVPP2
              Crosslinked polyethylene insulated PVC sheathed wire braided copper tape around the package block frequency conversion power cable.
              BPYJVP3
              Cross-linked polyethylene insulated PVC sheathed aluminum polyester composite film around the package block frequency conversion power cable.

              Note: copper wire in the conductor wire core can be used in a tin, flame retardant cable type before adding ZR, soft cable structure and R.
              Eight, code name and meaning:

              Code name
              Symbol meaning
              BP
              Frequency conversion power cable
              Copper conductor
              omit
              G
              Silicone rubber insulation or sheath
              F
              F46 insulation or sheath
              V
              PVC insulated and sheathed
              YJ
              Cross-linked polyethylene insulation
              VF
              sheath
              P(P1)
              Braided copper shield (tin braided shielding)
              P2
              Copper strip winding and shielding
              P3
              Aluminum polyester composite film winding and shielding
              PP2
              Copper wire braided copper tape winding and shielding

              Nine, cable specifications:

              model
              some
              Nominal cross section was,
              All the models
              3 + 3
              3 + 1
              1
              4,6,10,16,25,35,50,70,95,
              120150185240
              The main core of nominal section was
              Grounding wire core section was
              4
              1 (0.75)
              6
              1.5 (1)
              10
              2.5 (1.5)
              16, 25
              4 (2.5)
              35
              6
              50, 70
              10
              95
              16
              120, 150
              25
              185
              35
              240
              50 (35)

              Ten, basic cable specifications and structure parameters:

              Wire core * nominal section (was)
              Conductor structure
              (Root number * diameter)
              mm
              Maximum overall diameter (mm)
              BPVVPP2
              BPYJVPP2
              BPGGPP2
              3 * 4
              1/2.26
              13.5
              15.5
              3 * 6
              1/2.78
              14..0
              16.0
              3 * 10
              7/1.35
              19.0
              21.0
              3 * 16
              7/1.70
              22.0
              24.0
              3 * 25
              7/2.15
              25.0
              26.5
              3 * 35
              7/2.52
              26.0
              35.5
              3 * 50
              10/2.52
              28.5
              40.0
              3 * 70
              14/2.52
              31.5
              43.5
              3 * 95
              19/2.52
              36.5
              50.0
              3 * 120
              24/2.52
              40.0
              56.0
              3 * 150
              30/2.52
              45.0
              60.0
              3 * 185
              37/2.52
              47.0
              67.0
              3 * 4 + 3 * 0.75
              1/2.26
              14.5
              16.5
              3 * 6 + 3 * 1
              1/2.78
              15.0
              17.0
              The 10 + 3 * 3 * 2.5
              7/1.35
              20.8
              22.0
              16 + 3 * 3 * 2.5
              7/1.70
              23.0
              25.0
              25 + 3 * 3 * 4
              7/2.15
              28.0
              27.5
              35 + 3 * 3 * 6
              7/2.52
              32.0
              36.5
              50 + 3 * 3 * 10
              10/2.52
              37.0
              41.0
              70 + 3 * 3 * 10
              14/2.52
              41.6
              44.5
              95 + 3 * 3 * 16
              19/2.52
              47.0
              51.0
              120 + 3 * 3 * 25
              24/2.52
              50.1
              57.0
              150 + 3 * 3 * 25
              30/2.52
              52.0
              61.0
              185 + 3 * 3 * 35
              37/2.52
              58.5
              68.0

              11 technical data:
              1, according to DIN VDE fifth class soft stranded copper conductors.
              2 insulation, weather resistance and heat-resistant resin.
              3, soft shield.
              Along with the development of the frequency control drive technology, more and more high to the requirement of the variable frequency drive system, especially for the fast switch IG BT semiconductor modern frequency conversion technology, though it has high pulse frequency and more time only milliseconds, but they would have a positive magnetic field on the surrounding environment.In order to make the inverter work normally, not affected by electromagnetic interference, so the connection between the inverter and three phase ac motor cable requires has anti-jamming performance, low effective capacitance and low transfer impedance.


              Browse:
              Return To The Top

              分亯到(dao):

              VAiWz

                  <tr id="kljy-1q"><address></address></tr>

                    1. <i id="kljy-1q"></i>
                        <tbody id="kljy-1q"></tbody>
                      1. <address><small id="kljy-1q"></small></address>