              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              The electronic computer shielded cable

              電子計(ji)算(suan)機屏蔽電纜(lan).jpg
              • 電子計算(suan)機(ji)屏(ping)蔽電(dian)纜(lan).jpg
              Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other…

              Description:

              A, product characteristics and USES:
              Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other industrial and mining enterprises and distributing system, computer system, signal transmission of the automation system and testing instruments, meters and other connection with multiple of shielded cable.
              Second, the electronic computer shielded cable using features:
              Working temperature: general type does not exceed 70 ℃, after the model 105 is highest do not exceed 105 ℃.
              Minimum ambient temperature: fixed installation to 40 ℃ the fixed installation to 15 ℃
              The rated voltage Uo/U: 300/500 v
              The minimum bending radius: no armoured layer cable should be not less than 6 times of cable diameter
              Layer with armored cable should be not less than 12 times of cable diameter
              Three, computer shielded cable main technical indicators:

              Performance of the projectunitTechnical indicators
              Polyethylene insulationPVC insulated
              Insulation resistance when 20 ℃As a line between the conductorsM Ω · km50025
              Between the shielding line11
              Capacitance (1 KHZ)Type 3pF/m75200
              1 and 290
              Capacitance unbalance (1 KHZ)pF/M1/
              Inductive resistance thanCross sectionMu h/Ω20
              20
              25
              35
              20
              20
              25
              35

              0.5mm2
              0.75mm2
              1.0mm2
              1.5mm2






              Shielding inhibition coefficient or less
              0.010.01
              Test voltageV/1min10001000
              Flame retardant
              Comply with the requirements of 12666-90Comply with the requirements of 12666-90

              Four, computer shielded cable type:


              projectCode nameinstructions
              Flame retardant code/
              ZR
              ZRA
              ZRB
              ZRC
              The flame retardant can be omitted
              Flame retardant
              Grade A flame retardant
              Class B fire retardant
              Class C fire retardant
              A series of codesDJThe electronic computer (including DCS system) and electric instrument
              Insulation materialsY
              V
              D
              W
              polyethylene
              Polyvinyl chloride (PVC)
              Low smoke low halogen polyvinyl chloride (PVC)
              Low smoke zero halogen polyvinyl chloride olefins
              Shielding materialsP
              P1
              P2
              P3
              Copper wire braided
              Tin plated copper wire weaving
              Copper/polyester composite membrane
              Aluminum/polyester composite membrane
              Sheath materialY
              V
              D
              W
              Heat resistant polyethylene
              Polyvinyl chloride (PVC)
              Low smoke low halogen polyethylene
              Low smoke zero halogen polyolefin
              Armoring materials22Steel tape armoured
              Conductor typeA
              B
              R
              Single strand conductors
              Seven strands of stranded conductor
              More flexible conductor
              specifications
              Fill in the logarithmic x (unit some x conductor cross section)
              Logarithmic N: 1, 2, 3,......19
              Unit some n: 2, 3
              S: conductor section 0.5, 0.75, 1.0, 1.5, was


              Browse: