              Rosemount 3051L Flanged Installed Level Transmitter

              儸斯(si)矇特(te)3051L灋(fa)蘭安(an)裝(zhuang)液位變(bian)送(song)器.jpg
              • 儸(luo)斯矇特(te)3051L灋(fa)蘭安(an)裝(zhuang)液位(wei)變(bian)送(song)器.jpg
              Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier desig…

              Description:

              Productoverview:
              Ross Monte 3051L flange mounted liquid level transmitter Due to the adoption of ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type. ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier.
              Two, work principle:
              When working, the high and low pressure side of the diaphragm and the filled liquid transmit the process pressure to the filling liquid filled liquid, then transmits the pressure to the center of the sensing diaphragm sensor. The sensing membrane is a elastic element of tension, compression and displacement with the change (for GP gauge transmitter, atmospheric pressure as applied in the low voltage side of the sensing membrane.). The AP absolute pressure transmitter, low voltage side always maintain a reference pressure. The sensing membrane Zui large displacement is 0.004 inches (0.1 mm), and the displacement is proportional to pressure. The capacitor plates on both sides of the diaphragm position detection sensor. The difference between the capacitance sensing diaphragm and capacitor plate is converted to the corresponding voltage or current, HART (high speed digital data highway addressable remote transmitter output signal).
              Third, widely used:
              For the measurement of gas, liquid and vapor pressure, and then turn it into a current signal output 4-20mADC. Can HART375, 475 hand operator to communicate with each other, setting and monitoring through them.
              Fourth, the main features:
              1, 5 years of continuous work without adjustment;
              2, the temperature effect is negligible;
              Influence of static pressure can be ignored;
              3, one-way impact: 100 thousand consecutive unidirectional overvoltage overvoltage after the experiment affect the amount of less than 0.03%;
              4, improve the self diagnosis function;
              5, small, lightweight (standard 3.9kg);
              6, static effects are neglected:
              When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence).
              7, excellent properties of unidirectional overvoltage:
              The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
              Five, technical parameters:
              The 1. level measurement accuracy of 0.075%;
              2. calibration range from 0.25inH2O to 8310inH2O;
              3. flat film chip, 2-, 4-, and inch extend type diaphragm;
              4. kinds of filling liquid optional, can meet the requirements of different applications;
              5. clever and lightweight, easy installation and maintenance;
              6. liquid material: 316L stainless steel, Hastelloy, tantalum.
              Six, selection table:

              Model

              Product name

              3051L

              Flange mounted liquid level transmitter

              Code

              Pressure range (range /zui Small range)

              Two

              -250 to 250inH Two O/2.5H Two O (-62.2KPa to 62.2KPa/0.62KPa)

              Three

              -1000 to 1000inH Two O/10H Two O (-248KPa to 248KPa/2.5KPa)

              Four

              -8310 to 8310inH Two O/83.1H Two O (-2070KPa to 2070KPa/20.7KPa)

              Code

              output

              A

              4-20mA Based on a HART Digital signal protocol

              M

              Low power consumption, 1-5VDC Based on a HART Digital signal protocol ( 0.8-3.2VDC Output option code C2 )

              F

              FF Bus

              W

              PROFIBUS

              Code

              Diaphragm size

              Material Science

              Extended length

              Notes

              G0

              2in./DN 50

              316L SST

              Only the plane type

              Extension with diameterEighty The Conduit

              Size. Of Forty Pipe size,

              Please consult factory.

              H0

              2in./DN 50

              Hastelloy C-276

              Only the plane type

              J0

              2in./DN 50

              tantalum

              Only the plane type

              A0

              3in./DN 80

              316L SST

              Plane type

              A2

              3in./DN 80

              316L SST

              2in./50mm

              A4

              3in./DN 80

              316L SST

              4in./100mm

              A6

              3in./DN 80

              316L SST

              6in./150mm

              B0

              4in./DN 100

              316L SST

              Plane type

              B2

              4in./DN 100

              316L SST

              2in./50mm

              B4

              4in./DN 100

              316L SST

              4in./100mm

              B6

              4in./DN 100

              316L SST

              6in./150mm

              C0

              3in./DN 80

              Hastelloy C-276

              Plane type

              C2

              3in./DN 80

              Hastelloy C-276

              2in./50mm

              C4

              3in./DN 80

              Hastelloy C-276

              4in./100mm

              C6

              3in./DN 80

              Hastelloy C-276

              6in./150mm

              D0

              4in./DN 100

              Hastelloy C-276

              Plane type

              D2

              4in./DN 100

              Hastelloy C-276

              2in./50mm

              D4

              4in./DN 100

              Hastelloy C-276

              4in./100mm

              D6

              4in./DN 100

              Hastelloy C-276

              6in./150mm

              E0

              3in./DN 80

              tantalum

              Only the plane type

              F0

              4in./DN 100

              tantalum

              Only the plane type


              Code

              Installation flange size

              Rating

              Material Science

              Applicable to high voltage side of diaphragm size

              M

              2in.

              One hundred and fifty level

              carbon steel

              2 in./DN50

              A

              3in.

              One hundred and fifty level

              carbon steel

              3 in./DN80

              B

              4in.

              One hundred and fifty level

              carbon steel

              4 in./DN100

              N

              2in.

              Three hundredlevel

              carbon steel

              2 in./DN50

              C

              3in.

              Three hundredlevel

              carbon steel

              3 in./DN80

              D

              4in.

              Three hundredlevel

              carbon steel

              4 in./DN100

              P

              2in

              Six hundredlevel

              carbon steel

              2 in./DN50

              E

              3in.

              Six hundredlevel

              carbon steel

              3 in./DN80

              X

              2in.

              One hundred and fifty level

              SST

              2 in./DN50

              F

              3in.

              One hundred and fifty level

              SST

              3 in./DN80

              G

              4in.

              One hundred and fifty level

              SST

              4 in./DN100

              Y

              2in.

              Three hundredlevel

              SST

              2 in./DN50

              H

              3in.

              Three hundredlevel

              SST

              3 in./DN80

              J

              4in.

              Three hundredlevel

              SST

              4 in./DN100

              Z

              2in.

              Six hundredlevel

              SST

              2 in./DN50

              L

              3in.

              Six hundredlevel

              SST

              3 in./DN80

              Q

              DN 50

              PN 10-40

              carbon steel

              2 in./DN50

              R

              DN 80

              PN 40

              carbon steel

              3 in./DN80

              S

              DN 100

              PN 40

              carbon steel

              4 in./DN100

              V

              DN 100

              PN 10/16

              carbon steel

              4 in./DN100

              K

              DN 50

              PN 10-40

              SST

              2 in./DN50

              T

              DN 80

              PN 40

              SST

              3 in./DN80

              U

              DN 100

              PN 40

              SST

              4 in./DN100

              W

              DN 50

              PN 10/16

              SST

              4 in./DN100


              Code

              The process of oil filling -High pressure side

              Temperature limit

              A

              Syltherm XLT

              -75 to One hundred and fifty C (-102 to302 ~ F)

              C

              D.C.704 silicone oil

              Zero to Two hundred and five C (32 to401 degrees F)

              D

              D.C.200 silicone oil

              -45 to Two hundred and five C (-49 to401 degrees F)

              H

              Inert liquid

              -45 to One hundred and seventy-five C(-49 to 347 degrees F)

              G

              Glycerin and water

              -15 to Ninety-five C (5 to 203 degrees F)

              N

              Neobee M-200

              -15 to Two hundred and five C (5 to 401 degrees F)

              P

              Propylene glycol and water

              -15 to Ninety-five C (5 to 203 degrees F)


              Code

              option


              Header

              M (1)

              Linear meter, 0-100% scale

              M3 (1)

              The special calibration table, specify the range

              M4 (1)

              LCD Header, 0-100%

              M7 (1)

              LCD First, linear, special set


              Hazardous area certification

              E5

              The Canadian Standards Association (CSA) Flameproof certification

              I5 (2)

              Factory mutual (FM) Non flammable and safety certification

              K5

              Factory mutual (FM) Flameproof and intrinsically safe comprehensive certification

              C5 (3)

              Canada certification industry and Science ( Only Canada )

              C6 (2)

              I6 and E6 Combination, CSA Flameproof and intrinsically safe certification


              ( Requirement Zui High power supply voltage 42.4Vdc)

              K6

              CSA/CENELEC Flameproof and intrinsically safe certification

              EF (4)

              China NEPSI, GB Flameproof certification standard

              EF (2) (4)

              China NEPSI, GB Standard essential safety certification

              E4

              Japanese industrial standard (JIS) Flameproof certification

              E7

              The Standards Association of Australia (SAA) Flameproof certification

              E8

              CESI/CENELEC Flameproof certification

              I1 (2)

              BASEEFA The essence of security authentication

              I7 (2)

              The Standards Association of Australia (SAA) The essence of security authentication

              I8 (5)

              CESI/CENELEC The essence of security authentication

              N1 (2)

              BASEEFA N Type certification

              N7

              The Standards Association of Australia (SAA) Non flammable safety certification

              IC (2)

              SEV The essence of security authentication


              Other options

              W5

              copper O Ring type, used for vacuum occasions (non wetted parts)

              Q4

              Check data sheet

              Q8 (6)

              Material traceability, in accordance with EN 10204 3.1B

              L4

              316 SST Flange and bolt joints

              V1

              Inverting output

              V2

              4-20mV test signal

              V3

              20-100mV test signal

              Z1 (7)

              4- Line, 0-20mA output

              Z2 (7)

              4- Line, 0-16mA output

              Z3 (7)

              4- Line, 0-10mA output

              F_

              From table flush connection options in selecting a set of code

              Seven typical models:

              3051L2AG0RD21AAK5M5Q4
              3051L2AH0KD21AAM5
              3051L3AA0FD21AB



              Browse: