              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              Explosion-proof thermal resistance

              6防爆(bao)型(xing)熱電阻(灋(fa)蘭式(shi))01.png
              • 6防爆(bao)型(xing)熱(re)電(dian)阻(灋(fa)蘭式(shi))01.png
              WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal r…

              Description:

              Productoverview:

              WZP-240 series Explosion-proof thermal resistance The structure, principle and assembly of thermal resistance is basically the same, the difference is, flameproof or intrinsically safe explosion-proof junction box products (shell) special structure is adopted in the design, wiring box with high strength Aluminum Alloy die casting, and has sufficient internal space, wall thickness and mechanical strength, thermal stability of rubber seal the rings are in line with national standards. So, when the explosive mixed gases inside the enclosure when the explosion occurred, the internal pressure will not destroy the junction box, and the resulting heat is not the outward diffusion of detonation.

              Two, work principle:
              WZP-240 series Explosion-proof thermal resistance The gap explosion-proof junction box component design principle, with sufficient strength, all can produce a spark, arc and dangerous temperature components are sealed in a box cavity, when the cavity when the explosion occurred, the joint gap flameout and cooling, so that the explosion flame and temperature transmission to the outside of the cavity, thereby temperature measurement.
              Three, application:
              WZP-240 series Explosion-proof thermal resistance Usually, record and display instruments using instruments, electronic computing and other supporting. Direct measurement of hydrocarbons in the production site and other explosives -200 ~ C~500 ~ C range of liquid, steam and gas and solid surface temperature.
              Four, main features:
              1, various forms of explosion-proof, explosion-proof performance;
              2, large measuring range;
              3, high mechanical strength, good pressure resistance.
              4, a spring type temperature sensing element, good seismic performance;
              Five, technical parameters:
              Product executive standard
              IEC751
              JB/T18622-1997
              JB/T8623-1997
              JB/T5518-91
              Insulation resistance at room temperature
              Heat resistance at ambient temperature is 15 to 35 DEG C, relative humidity is less than 80%, the test voltage is 10 - 100V (DC) >100M. The insulation resistance between electrode and outer tube.

              Six, installation method:
              1, first of all should measure the good thermal resistance thread thread or flange size, supporting flange or thread processing base.
              2, according to the size of the base flange or threaded hole in the pipe, to be measured.
              3, the flange or the screw tooth of the welding. The flange or thread is inserted has opened hole in the flange or threaded seat base and pipeline measured welding.
              4, the screw base thermal resistance with bolts or threaded in has been welded.
              5, in accordance with the wiring diagram of the terminal box thermal resistance grounding line, and the display instrument is connected on the dial corresponding. Connection box can not contact with the wall of the measured medium pipeline, ensure the junction box temperature not exceeding 100 DEG C. Outlet hole junction box should prevent due to poor sealing water vapor, dust deposition caused by short circuit terminal.

              Seven, measurement range and tolerance:

              Model

              Graduation

              The temperature range of C DEG

              Precision grade

              Tolerance

              WZP240

              Pt100

              -200-+500

              A

              (0.15+0.002 + LTL)

              WZC240

              Pt100

              -200-+500

              B

              (0.30+0.005ltl).

              Eight, selection table:

              Code

              WZ - - - - - - - - - - - - - / - armored thermal resistance

              W

              Temperature meter (Zhongwei control)


              Code


              Z

              Heat resistance


              Code

              The temperature measuring element

              P

              Pt100 Pt1000 (the order required)

              C

              Cu50


              Code


              K

              Armoured type (assembled the symbol)


              Code



              Single

              Two

              Double branch


              Code

              Installation assembly (armoured)

              Zero

              No protection tube

              One

              No fixed device

              Two

              Fixed thread

              Three

              Movable flange

              Four

              Fixed flange

              Five

              90 degree angle flange

              Six

              Fixed thread taper

              Code

              Installation of armor type

              One

              No fixed device

              Two

              The fixed clip sleeve thread

              Three

              Flecible thread

              Four

              The fixed clip sleeve flange

              Five

              The movable ferrule flange


              Code

              Connection box

              Zero

              Simple type

              One

              Ordinary type

              Two

              Splash proof (waterproof type substitution)

              Three

              Waterproof type

              Four

              Explosion proof type

              Six

              Socket type

              Seven

              With the connecting wire type


              Code

              Armoured armoured body diameter

              Three

              Phi 3mm

              Four

              Phi 4mm

              Five

              Phi 5mm

              Six

              Phi 6mm

              Eight

              Phi 8mm

              Code

              The diameter of the outer protection tube assembly (full armor)

              Zero

              Phi 16mm

              One

              Phi 12mm

              Heat resistance A By ordering protocol.

              Note: the connector form, convenient installation, suitable for measuring -200-450 Liquid, gas and solid surface temperature range.

              The design and selection of notes:
              1, model;
              2, division no.;
              3, precision grade;
              4, fixed form;
              5, the length or depth of insertion.
              Customer service service commitment:
              1, my company sold Zhongwei Thermal resistance series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


              Browse: