              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              The thermal resistance of remote bimetal thermometer

              5電(dian)阻遠傳雙(shuang)金屬(shu)溫度計.PNG
              • 5電(dian)阻(zu)遠傳雙金屬(shu)溫度(du)計(ji).PNG
              WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of …

              Description:

              Productoverview:
              WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of temperature instruments, to overcome the traditional thermometer single expansion performance and short service life and poor reliability, the disadvantages of large volume temperature package. The temperature sensor of steam and gas volume respectively than the traditional pressure type thermometer reduced by 30 and 60 times, creatively or platinum copper heat resistance temperature sensor mounted on the measuring element, realize the function of temperature measurement of electromechanical integration. Formed by the liquid pressure type temperature is extremely basic temperature measuring instrument for remote transmission, explosion-proof, anti-corrosion, shockproof, electrical connector, temperature signal transmission and other functions, a series of temperature meter.

              Two, work principle:
              WSSP series The thermal resistance of remote bimetal thermometer Is a kind of thermal resistance temperature sensor and WSSP type thermometer temperature package installed in the same temperature element within a temperature measuring instrument. Two measurement systems are independent of each other, do not affect the temperature measurement accuracy and their. The outstanding advantages of this instrument is just a single point temperature measurement can double indicate the measured temperature, the pressure for the instructions, the thermal resistance signal for transmission to the control room (about 500 meters), with two meter line, to control and adjust the measured temperature, the two temperature measurement system to monitor each other, improve the temperature measurement accuracy and reliability.
              Three, application:
              WSSP series The thermal resistance of remote bimetal thermometer Not only meet the temperature requirements, but also to meet the needs of long-distance transmission, remote double metal thermometer can directly measure the production process in a variety of -40 ~ +600 temperature range of liquid, gas and steam medium and solid surface temperature measurement.
              Four, main features:
              1, a temperature probe of small, high sensitivity, linear scale, long service life etc..
              2, with remote output resistance signal (PT100), shock resistance, corrosion resistant function and large power switch signal etc..
              3, structure and international similar products, can replace imported.
              Five, technical parameters:
              1, the temperature range of -40 to 600 DEG c;
              2, the ambient temperature of -10 to 55 DEG c;
              3, the relative humidity is less than or equal to 95%;
              4, precision grade 1.5;
              5, the time constant is less than or equal to 60S;
              6, the probe voltage is less than or equal to 6Mpa;
              7, probe diameter: 8-10mm diameter, movable external thread: M27*2;
              8, thermal resistance PT100 (single channel, dual output or 4-20mA output current).

              Six, matters needing attention:
              1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
              2, installation, non twist instrument shell.
              3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
              4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
              5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
              6, do not use media exposure in measuring container.
              7, the use of the process should pay attention to check in time, probably in about 6 months.

              Seven, technical data sheet: 

              type Number

              Graduation

              The measuring range of C

              Precision grade

              Protection tube material

              Insertion length

              WSSE-401

              E

              -80 ~ +40

              Forty ~+80

              Zero ~Fifty

              Zero ~One hundred

              Zero ~One hundred and fifty

              Zero ~Two hundred

              Zero ~Three hundred

              Zero ~Four hundred

              Zero ~Five hundred

              One point five

              1Cr18Ni9Ti

              Three hundred and four ;

              Three hundred and sixteen; 

              316L ;

              Harrington

              C-276

              One hundred and fifty

              Two hundred

              Three hundred

              Four hundred

              Five hundred

              Seven hundred and fifty

              One thousand

              WSSE-501

              WSSE-411

              WSSE-511

              WSSE-481

              WSSE-581

              WSSP-401

              Pt100

              WSSP-501

              WSSP-411

              WSSP-511

              WSSP-481

              WSSP-581

              WSSXE-401

              E

              WSSXP-401

              Pt100

              WSSXE-411

              E

              WSSXP-411

              Pt100

              WSSXE-481

              E

              WSSXP-481

              Pt100

              Eight, temperature range:

              The measuring range of C

              Applicable scope

              Industrial and commercial

              Laboratory and small

              -80 ~ +40

              B.

              B.

              -40 ~ +80

              B.

              B.

              0~50

              B.

              B.

              0~100

              B.

              B.

              0~150

              B.

              B.

              0 ~ 200

              B.

              B.

              0 ~ 300

              B.

              B.

              0~400

              B.

              B.

              0~500

              B.

              B.

              Remarks:
              One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
              Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than Forty Second, diameter Phi 10 When the time constant is less than Thirty Seconds.
              Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

              Nine, shape and size:

              structural style

              A

              B

              C

              E

              L

              D

              The axial type double metal thermometer

              Sixty-five

              Twenty-three

              Seventy-three

              -

              Seventy-five
              One hundred
              One hundred and fifty
              Two hundred
              Three hundred
              Four hundred
              Five hundred
              Seven hundred and fifty
              One thousand

              Phi 6
              Phi 8
              Phi 10

              One hundred and five

              Twenty-three

              Seventy-three

              -

              One hundred and fifty-five

              Twenty-three

              Seventy-three

              -

              The radial type double metal thermometer

              Sixty-five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              135 degrees to type double metal thermometer

              One hundred and five

              Twenty-three

              Eighty-five

              -

              One hundred and fifty-five

              Twenty-three

              Eighty-five

              -

              Universal type double metal thermometer

              One hundred and five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              One hundred and fifty-five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              Ten, the selection of encoding:

              Serial number

              category

              Specifications

              Explain

              WSS

              P

              Thermal resistance type

              Double metal thermometer (Zhongwei control)

              Dial diameter

              -3


              Phi 60

              -4


              Phi 100

              -5


              Phi 150

              Dial form

              Zero


              The axial (straight)

              One


              Radial (angle)

              Two


              135 degrees to (an obtuse type)

              Eight


              Universal (angle adjustable type)

              Fixed form

              Zero


              No fixed device

              One


              Movable external thread

              Two


              The movable internal thread

              Three


              Fixed thread

              Four


              Fixed flange

              Five


              Card set screw

              Six


              Sleeve flange

              Type of protection

              -


              Ordinary type

              W


              Type of protection

              F


              Anti-corrosion type

              Cases: The axial type, PT100 type, I temperature range of 0-400 DEG c.. Activity thread M27x2, protective tube insertion length is 316 300mm. WSSP-401 0-400 l=300mm I: C protection tube 316.

              The design and selection of notes:
              1, model;
              2, the thermal resistance index number;
              3, the thermal resistance precision grade;
              4, double metal thermometer precision grade;
              5, temperature range;
              6, fixed form;
              7, protection tube material;
              8, the inserted length.
              Customer service service commitment:
              1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


              Browse:
              Return To The Top