              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              Explosion proof type double metal thermometer

              5防爆(bao)型(xing)遠(yuan)傳(chuan)雙(shuang)金屬溫度計(ji).jpg
              • 5防(fang)爆型遠傳雙金屬溫度(du)計(ji).jpg
              WSSB series Anti Burst type double metal thermometer Is a suitable measurement, low temperature fiel…

              Description:

              Productoverview:
              WSSB series Anti Burst type double metal thermometer Is a suitable measurement, low temperature field detection instrument, can be used to directly measure the temperature of the gas, liquefied. Compared with the domestic similar products: precision instrument level reaches 1, the meter shell made of anti-corrosion materials, its temperature can reach 200 DEG C, Zui low -40 C. Flange type structure, double sealing ring, the anticorrosion, good waterproof performance. The protective tube welded by automatic argon protection tube, solid weld, small intergranular corrosion.The dial is aluminum oxide printing plate, clear surface styling. For the adjustable pointer.
              Two, work principle:
              <strong> Anti</strong> WSSB series Burst type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
              Three, application:
              <strong> Anti</strong> WSSB series Burst type double metal thermometer With the installation of all kinds of casing, meet different pressure level requirements. Can be directly measured in various production processes within the range of -80-+500 DEG C liquid, steam and gas and solid surface temperature.
              Four, main features:
              1, the scene display temperature, convenient safe and reliable, long service life;
              2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
              3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
              4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
              5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
              Five, technical parameters:
              The implementation of standards
              JB/T8803-1998 GB3836-83.
              Other parameters
              Dial diameter: 60100150;
              The accuracy level: (1, 1.5);
              Thermal response time: less than 40S;
              Protection grade: IP55;
              Angle adjusting error: angle adjustment error should not exceed the range of 1%;
              Return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
              Repeatability: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

              Six, matters needing attention:
              1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
              2, installation, non twist instrument shell.
              3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
              4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
              5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
              6, do not use media exposure in measuring container.
              7, the use of the process should pay attention to check in time, probably in about 6 months.


              Seven, temperature range:

              The measuring range of C

              Applicable scope

              Industrial and commercial

              Laboratory and small

              -80 ~ +40

              B.

              B.

              -40 ~ +80

              B.

              B.

              0 ~ 50

              B.

              B.

              0~100

              B.

              B.

              0~150

              B.

              B.

              0~200

              B.

              B.

              0 ~ 300

              B.

              B.

              0~400

              B.

              B.

              0~500

              B.

              B.

              Eight, dimensions:

              form

              D

              A

              B

              E

              D

              Radial type

              One hundred and five

              Twenty-three

              Seventy-three


              With 8

              With 10

              One hundred and fifty-five

              Twenty-three

              Seventy-three


              Axial type

              Sixty-five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              Universal type

              One hundred and five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              One hundred and fifty-five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              Electric contact

              Axial type

              One hundred and twenty-eight

              Forty

              One hundred and thirty-five


              Electric contact

              Radial type

              One hundred and twenty-eight

              Seventy-two

              One hundred and fifty

              Forty-two

              Electric contact

              Universal type

              One hundred and twenty-eight

              Forty

              One hundred and seventy-five

              Ninety-eight

              9, models and specifications:

              Model

              The measuring range of C

              Precision grade

              Protection tube material

              Specifications

              Mounting device

              WSSB-410

              -80-+40

              -40-+80

              0-50

              0-100

              0-150

              0-200

              0-300

              0-400

              0-500

              One point five

              1Cr18NI9Ti

              Three hundred and four

              Three hundred and sixteen

              316L

              Hastelloy C-276

              H.AIIoyc-276

               

              Seventy-five

              One hundred

              One hundred and fifty

              Two hundred

              Three hundred

              Four hundred

              Five hundred

              Seven hundred and fifty

              One thousand

              No screw fixing device

              WSSB-480

              WSSB-411

              Movable external thread

              WSSB-481

              WSSB-412

              The movable internal thread

              WSSB-482

              WSSB-413

              Fixed flange

              WSSB-483

              WSSB-414

              Fixed thread

              WSSB-484

              WSSB-415

              Card set screw

              WSSB-485

              WSSB-416

              Sleeve flange

              WSSB-486

              Example: Zhongwei flameproof universal type double metal thermometer, a regulating upper temperature range Zero ~Four hundred C, protective tube Three hundred and sixteen Insert, length 300mm WSSX-481BM 0 ~ Four hundred C L=300Protection tube Three hundred and sixteen .

              Ten, the selection of encoding:

              Serial number

              category

              Specifications

              Explain

              WSS

              B

              Explosion proof type

              Double metal thermometer (Zhongwei control)

              Dial diameter

              -3


              Phi 60

              -4


              Phi 100

              -5


              Phi 150

              Dial form

              Zero


              The axial (straight)

              One


              Radial (angle)

              Two


              135 degrees to (an obtuse type)

              Eight


              Universal (angle adjustable type)

              Fixed form

              Zero


              No fixed device

              One


              Movable external thread

              Two


              The movable internal thread

              Three


              Fixed thread

              Four


              Fixed flange

              Five


              Card set screw

              Six


              Sleeve flange

              Type of protection

              -


              Ordinary type

              W


              Type of protection

              F


              Anti-corrosion type

              Eleven, Design selection and ordering information:
              1, model;
              2, precision grade;
              3, temperature range;
              4, electric contact position adjustment;
              5, fixed form;
              6, the inserted length. 
              Customer service service commitment:
              1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


              Browse: