              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
              0517-86918678
              Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
              Tel:0517-86918678
              Fax:0517-86918679
              Email:zhongweick@https://szokazaki.com
              Post Encoding:211600

              Anti-corrosion type double metal thermometer

              5防腐(fu)型雙(shuang)金屬(shu)溫度(du)計02.png
              • 5防腐(fu)型雙(shuang)金屬(shu)溫(wen)度計(ji)02.png
              WSSF series Anti-corrosion type double metal thermometer Is a kind of field measurement, suitable fo…

              Description:

              Productoverview:
              WSSF series Anti-corrosion type double metal thermometer Is a kind of field measurement, suitable for low temperature detection of industrial instrument can be used to directly measure the gas, liquid and steam temperature.Electric contact bimetallic thermometer can exceed the given values in the temperature, automatically sends out control signal to cut off power supply or alarm.
              Double metal thermometer has advantages of no mercury damage, easy reading, sensitive reaction and solid proof, can replace the industrial glass mercury thermometer, widely used in industrial and scientific research departments.Anticorrosion type instrument shell using Aluminum Alloy three spray paint or coating, protection tube, connecting columns made of 316L material, the connecting part adopts the sealing pad, temperature measurement can be applied in the most corrosive medium, gas.
              Two, work principle:
              WSSF series Anti-corrosion type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to.
              Three, application:
              WSSF series Anti-corrosion type double metal thermometer The shell adopts Aluminum Alloy three spray paint or coating, protection tube, connecting columns made of 316L material, the connecting part adopts the sealing pad, temperature measurement can be applied in the most corrosive medium, gas.
              Four, main features:
              1, the scene display temperature, convenient safe and reliable, long service life;
              2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
              3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
              4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
              5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
              Five, technical parameters:
              1, the implementation of standards: JB/T8803-1998 GB3836-83;
              2, dial diameter: 60100150;
              3, accuracy: (1, 1.5);
              4, thermal response time: less than 40S;
              5, protection grade: IP55;
              6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
              7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
              8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.
              Six, matters needing attention:
              1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
              2, installation, non twist instrument shell.
              3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
              4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
              5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
              6, do not use media exposure in measuring container.
              7, the use of the process should pay attention to check in time, probably in about 6 months.


              Seven, temperature range:

              The measuring range of C

              Applicable scope

              Industrial and commercial

              Laboratory and small

              -80 ~ +40

              B.

              B.

              -40 ~ +80

              B.

              B.

              0~50

              B.

              B.

              0~100

              B.

              B.

              0 ~ 150

              B.

              B.

              0 ~ 200

              B.

              B.

              0 ~ 300

              B.

              B.

              0~400

              B.

              B.

              0~500

              B.

              B.

              Eight, shape and size:

              form

              A

              B

              C

              E

              L

              D

              Axial type

              Sixty-five

              Twenty-three

              Seventy-three

              -

              Seventy-five
              One hundred
              One hundred and fifty
              Two hundred
              Three hundred
              Four hundred
              Five hundred
              Seven hundred and fifty
              One thousand

              Phi 6
              Phi 8
              Phi 10

              One hundred and five

              Twenty-three

              Seventy-three

              -

              One hundred and fifty-five

              Twenty-three

              Seventy-three

              -

              Radial type

              Sixty-five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              135 degrees to type

              One hundred and five

              Twenty-three

              Eighty-five

              -

              One hundred and fifty-five

              Twenty-three

              Eighty-five

              -

              Universal type

              One hundred and five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              One hundred and fifty-five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              Nine, technical data sheet:

              Serial number

              Model

              structural style

              Case diameter

              Protection tube diameter

              The protective tube length L

              Standard installation thread

              The temperature range C

              One

              WSSF-401

              Angle type

              Phi 126

              Phi 10

              Seventy-five
              One hundred
              One hundred and twenty
              One hundred and fifty
              Two hundred
              Two hundred and fifty
              Three hundred
              Four hundred
              Five hundred
              Seven hundred and fifty
              One thousand
              One thousand and two hundred
              One thousand and five hundred
              One thousand seven hundred and fifty
              Two thousand
              Two thousand and five hundred

              M27 * 2

              -60 - +40
              -40 - +60
              -20 - +80
              0 - 50
              0 - 100
              1 - 120
              0 - 150
              0 - 200
              0 - 300
              0 - 400
              0 - 500
              0 - 600

              Two

              WSSF-411

              Straight

              Phi 126

              Three

              WSSXF-401

              Electric contact angle

              Phi 126

              Four

              WSSXF-411

              Straight type electric contact

              Phi 150

              Five

              WSSF-501

              Angle type

              Phi 166

              Six

              WSSF-511

              Straight

              Phi 166

              Ten, the selection of encoding:

              Serial number

              category

              Specifications

              Explain

              WSS

              F

              Anti-corrosion type

              Double metal thermometer (Zhongwei control)

              Dial diameter

              -3


              Phi 60

              -4


              Phi 100

              -5


              Phi 150

              Dial form

              Zero


              The axial (straight)

              One


              Radial (angle)

              Two


              135 degrees to (an obtuse type)

              Eight


              Universal (angle adjustable type)

              Fixed form

              Zero


              No fixed device

              One


              Movable external thread

              Two


              The movable internal thread

              Three


              Fixed thread

              Four


              Fixed flange

              Five


              Card set screw

              Six


              Sleeve flange

              Type of protection

              -


              Ordinary type

              W


              Type of protection

              F


              Anti-corrosion type

              Eleven, design and ordering:

              Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.

              Customer service service commitment:
              1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.