              Universal type double metal thermometer

              5萬(wan)曏型雙金(jin)屬(shu)溫度(du)計.PNG
              • 5萬(wan)曏(xiang)型(xing)雙(shuang)金屬溫度計(ji).PNG
              WSS series Universal type double metal thermometer Compared with the domestic similar products: inst…

              Description:

              Productoverview:
              WSS series Universal type double metal thermometer Compared with the domestic similar products: instrument precision grade 1.0, instrument shell made of anti-corrosion materials, its temperature can be as high as 200 c, Zui low -40 C. Flange type structure, double sealing ring, the anticorrosion, good waterproof performance. The protective tube welded by automatic argon protection tube, solid weld, small intergranular corrosion. The dial is aluminum oxide printing plate, clear surface styling. For the adjustable pointer.
              Two, work principle:
              WSS series Universal type double metal thermometer Is the principle of expansion work in varying degrees of temperature change when using two different metals. Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet. In order to improve the measurement sensitivity, usually made of sheet metals of spiral shape. When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen. Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to. The measuring range of this instrument is about 200~650 DEG C, allowable error are 1% of range scale. The use of glass liquid thermometer thermometer and a rod is similar, but can be used in mechanical strength under the condition of higher requirements.
              Three, application:
              WSS series Universal type double metal thermometer It can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature. Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
              Four, main features:
              1, the scene display temperature, convenient safe and reliable, long service life;
              2, a variety of forms, can meet different requirements. Victims of mercury free, easy reading, strong shock.
              3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance.
              4, core pulling type thermometer can not stop short time maintenance or replacement of movement.
              5, integrated with axial type, radial type, 135 type, universal type, complete varieties, suitable for various on-site installation need.
              Five, technical parameters:
              1, the implementation of standards: JB/T8803-1998 GB3836-83;
              2, dial diameter: 60100150;
              3, accuracy: (1, 1.5);
              4, thermal response time: less than 40S;
              5, protection grade: IP65;
              6, adjust the angle error: adjustment angle error should not exceed the range of 1%;
              7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit;
              8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.

              Six, Matters needing attention:
              1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
              2, installation, non twist instrument shell.
              3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
              4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
              5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
              6, do not use media exposure in measuring container.
              7, the use of the process should pay attention to check in time, probably in about 6 months.

              Seven, temperature range:

              The measuring range of C

              Applicable scope

              Industrial and commercial

              Laboratory and small

              -80 ~ +40

              B.

              B.

              -40 ~ +80

              B.

              B.

              0~50

              B.

              B.

              0 ~ 100

              B.

              B.

              0 ~ 150

              B.

              B.

              0~200

              B.

              B.

              0~300

              B.

              B.

              0~400

              B.

              B.

              0~500

              B.

              B.

              Remarks:
              One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
              Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than FortySecond, diameter Phi 10 When the time constant is less than Thirty Seconds.
              Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

              Eight, shape and size:

              structural style

              A

              B

              C

              E

              L

              D

              The axial type double metal thermometer

              Sixty-five

              Twenty-three

              Seventy-three

              -

              Seventy-five
              One hundred
              One hundred and fifty
              Two hundred
              Three hundred
              Four hundred
              Five hundred
              Seven hundred and fifty
              One thousand

              Phi 6
              Phi 8
              Phi 10

              One hundred and five

              Twenty-three

              Seventy-three

              -

              One hundred and fifty-five

              Twenty-three

              Seventy-three

              -

              The radial type double metal thermometer

              Sixty-five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              One hundred and five

              Fifty

              One hundred and ten

              Thirty-four

              135 degrees to type double metal thermometer

              One hundred and five

              Twenty-three

              Eighty-five

              -

              One hundred and fifty-five

              Twenty-three

              Eighty-five

              -


              One hundred and five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              One hundred and fifty-five

              Twenty-three

              One hundred and seventy-eight

              One hundred and twenty

              Nine, the specific model name that said:

              Model

              Measuring range

              Precision grade

              Protection tube material

              Specifications

              Fixed form

              D

              L

              WSS-480

              -80 ~ +40
              -40 ~ +80
              0 ~ 50
              0 ~ 100
              0 ~ 150
              0 ~ 200
              0 ~ 300
              0~400
              0~500

              One point five

              1Cr18Ni9Ti
              Three hundred and four
              Three hundred and sixteen
              316L
              Hastelloy C-276

              Phi 100

              Seventy-five
              One hundred
              One hundred and fifty
              Two hundred
              Three hundred
              Four hundred
              Five hundred
              Seven hundred and fifty
              One thousand

              No fixed device

              WSS-580

              Phi 150

              WSS-481

              Phi 100

              Movable external thread

              WSS-581

              Phi 150

              WSS-482

              Phi 100

              The movable internal thread

              WSS-582

              Phi 150

              WSS-483

              Phi 100

              Fixed thread

              WSS-583

              Phi 150

              WSS-484

              Phi 100

              Fixed flange

              WSS-584

              Phi 150

              WSS-485

              Phi 100

              Card set screw

              WSS-585

              Phi 150

              WSS-486

              Phi 100

              Sleeve flange

              WSS-586

              Phi 150

              Ten, the selection of encoding:

              Serial number

              WSS


              Double metal thermometer (Zhongwei control)

              Dial diameter

              -3


              Phi 60

              -4


              Phi 100

              -5


              Phi 150

              Dial form

              Zero


              The axial (straight)

              One


              Radial (angle)

              Two


              135 degrees to (an obtuse type)

              Eight


              Universal (angle adjustable type)

              Fixed form

              Zero


              No fixed device

              One


              Movable external thread

              Two


              The movable internal thread

              Three


              Fixed thread

              Four


              Fixed flange

              Five


              Card set screw

              Six


              Sleeve flange

              Type of protection

              -


              Ordinary type

              W


              Type of protection

              F


              Anti-corrosion type

              The selection of examples:
              100, dial diameter, temperature range of 0~400 DEG C, level 1.5, rotatablemale thread M27 * 2 450mm, length WSS-481, 0~400 C, L=450, M27 * 2, 1.5.

              Eleven, ordering:
              Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion.
              Customer service service commitment:
              1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
              2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
              3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
              4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
              5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, 48 hours outside users arrive at the scene.


              Browse:
              Return To The Top

              分亯到:

              zSpSH

                  <tr id="kljy-1q"><address></address></tr>

                    1. <i id="kljy-1q"></i>
                        <tbody id="kljy-1q"></tbody>
                      1. <address><small id="kljy-1q"></small></address>