              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

              Pointer oval gear flowmeter

              11橢圓(yuan)齒(chi)輪流量計(ji)(指鍼式(shi))03.jpg
              11橢(tuo)圓(yuan)齒輪流量(liang)計(指(zhi)鍼(zhen)式)02.png
              11橢圓齒輪(lun)流量(liang)計(指(zhi)鍼(zhen)式)01.png
              • 11橢圓(yuan)齒(chi)輪流(liu)量(liang)計(ji)(指鍼(zhen)式)03.jpg
              • 11橢圓齒輪(lun)流量(liang)計(ji)(指(zhi)鍼式)02.png
              • 11橢圓齒輪(lun)流量(liang)計(ji)(指鍼式)01.png
              ZW - LC seriesPointer oval gear flowmeterIs one of the typical displacement meter, used for measurem…

              Description:

              ZW - LC seriesPointer oval gear flowmeterIs one of the typical displacement meter, used for measurement of pipeline fluid flow under certain pressure.It has a simple structure, reliable use and high accuracy, flow field has no special requirements for import and export of the pipe, the viscosity of the measured medium range and the characteristics of the flow range is very wide.And therefore is widely used in petroleum, chemical industry, medicine, transportation, food and other industrial and commercial sector of liquid flow detection.Lc series especially suitable for the measurement of oil fuel.

              Second, the working principle:

              ZW - LC series pointer the measurement part of the oval gear flowmeter is mainly composed of two mutually meshing elliptical gear and shell (measuring room), elliptical gear turn every week the parallelism of the measured medium quality for half moon volume 4 times, by the elliptical gear meteor millions of volume flow rate Q: Q = 4 n nu 0

              Type:

              N - the rotation of the elliptical gear frequency (r/s);

              Nu 0 - half moon part volume (Mr.).

              So, in the half moon volume of the oval gear flowmeter nu 0 given conditions, as long as the measure of elliptic gear rotational speed n, can know the measured medium flow.

              Elliptic flow meter flow signals (that is, the elliptic gear rotating speed n) showed that has two kinds of on-site display and remote transmission.

              In situ show that the gear rotation through a series of deceleration and adjust speed than institutions, directly connected to the instrument panel on the indicating needle, and the total amount after mechanical counter display.

              Far eastone shows mainly through the reduction gear after * magnet rotates, making spring relay contact with * magnet synchronization to make or break the rotation of the same frequency, thus far to another display instrument issued by electrical impulses.

              Applications:

              ZW - LC series pointer oval gear flowmeter for diesel, gasoline, jet fuel, lubricating oil metering, can cooperate with ZW - quantitatively control the flow totalizer.especially XMJA series, the series flow meter is mainly used in petroleum, chemical industry, oil products, etc.

              1, ZW - LC - A cast iron type flowmeter, it is widely used in all kinds of oil products and for the measurement of the cast iron is not corrosive liquid medium;

              2, ZW - LC - E cast steel type flowmeter, used in high pressure, low corrosive medium measurement;

              3, ZW - LC - B stainless steel type flowmeter is widely used in strong corrosive liquid medium, such as acid, alkali, salt and the measurement of organic compounds, etc.

              Four, the main features:

              1, high measuring accuracy;

              2, pipeline installation condition has no effect on measuring accuracy;

              3, can be used in high viscosity liquid measurement;

              4, wide range of degrees;

              5, direct reading instrument without external energy can directly obtain the cumulative, total amount, clear, easy to operate.

              Five, the technical parameters:

              1, the nominal diameter: DN10 ~ DN200;

              2, working temperature: - 10 ℃ ~ + 200 ℃;

              3, nominal pressure: 0.6 ~ 10 mpa;

              4, medium viscosity: 0.3 ~ 2000 mpa. S;

              5, precision grade: 0.2;0.5;

              6, quantity than: ";

              7, shell material: cast iron;Cast steel;Stainless steel;

              8, mode of power supply: 3.6 VDC built-in lithium battery (once in two years);Outside for 24 VDC (optional);

              9, output signal: 4 ~ 20 ma two wire;Pulse 0 ~ 1000 hz;RS232 / RS485 (or consultation according to the requirements of customers;QF or GF transmitter;

              10, protection level: IP65 IP67;

              11, explosion-proof level: Exia Ⅱ CT4 and Exd Ⅱ CT4;

              12, header display: pointer display (single cumulative flow);Liquid crystal display (total flow and transient flow);

              13, connection mode: flange.

              14, optional accessories: meter filter

              Flow meter filter is liquid pipeline and liquid flow meter of auxiliary equipment, it can be filter out all kinds of foreign bodies in the liquid, so as to prevent blockage and ensure the normal operation of the instrument.Ordinary filter shell USES cast iron, the mesh is made of stainless steel cloth.Stainless steel filter material are all made of acid steel.Diameter of 25 mm below the filter for y type, more than 40 mm for u.

              Six, error calculation and adjustment:

              1, the basic error of flowmeter, by the verification flow point of all measured values respectively press type calculation: (volume) E = Vm - 100% (V/V

              E - meter error (generally refers to the cumulative error) take two significant figures.

              The Vm - meter measured values (i.e., values)

              V - were revised, flowmeter standard device measured value (that is, the actual value) from the basic formula of error, when the Vm > V, flowmeter fundamental error for "+" values, said flowmeter is going faster.

              Vm < V, flowmeter basic error for "-", said flowmeter walked slowly.

              2, in order to make the error of flowmeter, within the basic error limit is often the need for error.By changing in counter namely inside a pair of adjusting gear (tooth) are adjusted to change the mechanical transmission ratio, so that the flow meter's worth to adjust.

              3, error adjustment can't change the flow characteristic of the flowmeter, the characteristic curve of artificially in a new coordinate system.

              4, in general, in the rules (or actual use) flow within the scope of its zui and zui small flow check point basic error range is not big five, the regulation accuracy of basic error limits, all can be adjusted by the error flowmeter qualified basic error.

              Flow meter has been used, usually with the adjustment of the original gear set first for error detection, and then according to the error of the specific situation to adjust error.

              Seven, measurement requirements:

              1, the flow measurement has nothing to do with the flow of the fluid, it is because the oval gear flowmeter is depend on the measured medium pressure head driving elliptical gear rotating and measure.

              2, the greater the viscosity of the medium, from gear and measuring the less empty clearance leakage of the leak out, therefore the greater the nuclear medium sticky skin, the smaller the leakage error, to measure more advantage.

              3, high measuring accuracy, suitable for high viscosity medium flow measurements, but not containing solid particles of fluid (solid particles will gear jammed, so that you can't measure traffic).If the mixed with gas in the liquid medium to be measured, can also cause measurement error.

              Installation method:

              1, before installation shall be thoroughly clean the pipe and filter in front of the meter installation, in order to prevent debris into the meter.When measured liquid containing gas, should install air separator.

              2, should pay attention to must take meter oval gear shaft United States level, namely the dial and perpendicular to the plane.Flow adjustment and start, shut off the valve should be installed in the import and export of flow meters respectively.

              3, flowmeter shell on the arrow pointing in the direction of piping shall be installed with the liquid flow in the same direction.

              4, the continuous flow of pipeline, the installation of flowmeter horizontal line should be equipped with a bypass valve, in order to regular cleaning and maintenance.On the vertical pipe flow meter, shall be installed in the bypass duct to prevent debris into the instrument.

              Nine, note:

              1, right after installation, in accordance with the requirements when using can ensure enough accuracy, usually the cumulative value of precision can reach 0.5, is a more accurate flow meters.

              2, however, if the use of the measured medium flow rate is too small, the instrument will highlight the influence of the leakage error, can't guarantee enough accuracy of measurement.

              3, therefore, different specifications of small zui using flow has a value, only when the actual measured flow is greater than the lower limit value, the measurement precision can be guaranteed.

              4, secondly, when using, pay attention to the temperature of the measured medium cannot be too high, otherwise not only can increase the measurement error, and there are may be stuck in the gear.

              5, therefore, in the instrument by using temperature range.Use for a long time after the gear flow meter, the internal gear are corrosion and wear and tear, which affect measurement accuracy.

              6, therefore, often should observe, and regularly check removed, if conditions permit calibration on a regular basis as far as possible.

              Ten,The dimensions:

              table1, the size of the standard shape: unit: mm

              Nominal diameter

              L

              H

              A

              B

              D

              D1

              N (a)

              Φ

              10

              150

              100

              165

              210

              90

              60

              4

              14

              15

              170

              118

              172

              226

              95

              65

              4

              14

              20

              200

              150

              225

              238

              105

              75

              4

              14

              25

              260

              180

              232

              246

              115

              85

              4

              14

              40

              245

              180

              249

              271

              145

              110

              4

              18

              50

              340

              250

              230

              372

              160

              125

              4

              18

              65

              420

              325

              270

              386

              180

              145

              4

              18

              80

              420

              325

              315

              433

              195

              160

              8

              18

              100

              515

              418

              370

              458

              215

              180

              8

              18

              150

              540

              515

              347

              557

              280

              240

              8

              23

              200

              650

              650

              476

              720

              335

              295

              12

              23

              table2, cast steel, cast steel, high viscosity, high temperature cast steel standard dimension: unit: mm

              Nominal diameter

              L

              H

              B

              A

              D

              D1

              N (a)

              Φ

              15

              200

              138

              232

              180

              105

              75

              4

              14

              20

              250

              164

              220

              160

              125

              90

              4

              18

              25

              300

              202

              252

              185

              135

              100

              4

              18

              40

              300

              202

              293

              208

              165

              125

              4

              23

              50

              384

              262

              394

              312

              175

              135

              4

              23

              80

              450

              337

              452

              332

              210

              170

              8

              23

              100

              555

              442

              478

              310

              250

              200

              8

              25

              150

              540

              510

              557

              347

              300

              250

              8

              26

              200

              650

              650

              720

              476

              36

              310

              12

              26

              Cast iron, cast steel, high temperature type standard dimension: DN15 ~ DN25, A and B size according to the above-mentioned data add 160 mm hot extension tube: DN40 ~ DN80, A and B size according to the size of the table with 300 mm hot extension tube, the rest of the size with the table size accordingly.
              Table 3, stainless steel type standard dimension: unit: mm

              Nominal diameter

              L

              H

              B

              A

              D

              D1

              N (a)

              Φ

              15

              208

              120

              228

              172

              95

              65

              4

              14

              20

              236

              150

              238

              225

              105

              75

              4

              14

              25

              287

              195

              246

              232

              115

              85

              4

              14

              40

              265

              178

              349

              265

              145

              110

              4

              18

              50

              265

              178

              349

              265

              160

              125

              4

              18

              65

              365

              260

              436

              319

              180

              145

              4

              18

              80

              420

              305

              459

              324

              200

              160

              8

              18

              100

              515

              400

              554

              373

              220

              180

              8

              18

              150

              540

              515

              607

              397

              280

              240

              8

              23

              Eleven, measuring range:
              Ordinary cast iron type (AType), cast steel,EType), stainless steel,B

              model

              ZW-LC-ACast iron

              ZW-LC-ECast steel

              ZW-LC-BStainless steel

              Nominal pressureMpa

              1.0 1.6

              2.5 4.0 6.4

              1.0 1.6

              Fluid viscosity to be tested

              2 ~200 Mpa.s

              Liquid temperature being measured

              - 20℃ ~+ 100

              flow The amount van wai m3/h

              model
              Precision grade

              ZW-LC-ACast iron

              ZW-LC-ECast steel

              ZW-LC-BStainless steel

              Nominal diameter
              mm

              0.5

              0.2

              0.5

              0.2

              0.5

              0.2

              10

              0.04~0.4

              0.1~0.4

              0.04~0.4

              0.1~0.4

              0.1~0.5

              0.1~0.5

              15

              0.25~1.5

              0.3~1.5

              0.25~1.5

              0.3~1.5

              0.3~1.5

              0.3~1.5

              20

              0.5~3

              0.6~3

              0.5~3

              0.6~3

              0.6~3

              0.6~3

              25

              1~6

              1.2~6

              1~6

              1.2~6

              1.2~6

              1.2~6

              40

              2.5~15

              3~15

              2.5~15

              3~15

              3~15

              3~15

              50

              4~24

              4.8~24

              4~24

              4.8~24

              4.8~24

              4.8~24

              65

              5~40

              8~40

              5~40

              8~40

              8~40

              8~40

              80

              10~60

              12~60

              10~60

              12~60

              12~60

              12~60

              100

              16~100

              20~100

              16~100

              20~100

              20~100

              20~100

              150

              32~190

              38~190

              32~190

              38~190

              38~190

              38~190

              200

              34~340

              68~340

              34~340

              68~340

              68~340

              68~340

              Twelve, selection of coding:

              The type code

              logo

              Material symbol

              Nominal diameter

              Nominal pressure

              counter

              transmitter

              precision

              Instructions (in the wei and control)

              ZW-LC-








              Oval gear flowmeter


              H







              Welded steel flow meter


              U







              Heat preservation jacket flowmeter


              N







              High viscosity liquid flow meter


              SP







              Food with a flow meter


              T







              High temperature type flowmeter


              Q







              Measuring gas flowmeter



              A






              Cast iron material



              E






              Cast steel material



              B






              Stainless steel material




              10





              For nominal diameter10mm




              15





              For nominal diameter15mm




              ……









              200





              For nominal diameter200mm





              1




              1.0MPa





              2




              1.6MPa





              3




              2.5MPa





              4




              4.0MPa





              6




              6.3MPa






              A ,A1



              Used forDN40The following,A1With the transmitter






              J1



              Used forDN50Above, can take transmitter






              A5 A6



              A5Single pointer word wheel display 
              A6
              Pointer cycle of zero







              GF-


              12VThree wire system photoelectric transmitter







              GF-


              24VThree wire system photoelectric transmitter







              MF


              4~20mATransmitter output







              DF


              Liquid crystal display with remote transmission4-20mA








              J1

              0.2Level of accuracy








              J2

              0.5Level of accuracy

              13, design selection and order notes:

              1, choose oval gear flow timing, it is suggested that according to the measured liquid flow control meter flow range of 30 ~ 70% choose specifications;According to the fluid temperature, and the size of the pipeline pressure, and corrosion properties of liquid viscosity, etc to select flowmeter types;

              2, when ordering, please specify the model of flow meter, diameter (mm), whether to ask explosion-proof, name of the medium, flow range (m3 / h), work pressure (MPa), temperature (℃), medium viscosity (MPa) s), to measure the corrosion medium, the user must also specify the medium corrosion properties, medium concentration (%), medium temperature (℃);

              3, this product can according to user requirements, within the header assembly electrical/current transmission device;

              4, when ordering parts, please click and fill in the figure, the collapse of the list;

              5, user, if you have special request, please put forward in order;

              6, our company can provide filters, venting device with flow meter, intelligent flow integrating instrument.

              After-sales service commitment:

              1, our company sold by flow meter series products within twelve months appear quality problem, is responsible for free maintenance.

              2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement.

              3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost.

              4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost.

              5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


              Browse:
              Return To The Top