              Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

              Ball valve plug-in vortex flowmeter

              5挿(cha)入(ru)式(shi)渦街流量(liang)計(帶毬閥(fa)).png
              • 5挿入(ru)式渦街(jie)流(liu)量(liang)計(ji)(帶毬閥(fa)).png
              Ball valve plug-in vortex flowmeter is inserted into the pipeline under test center, measurement of …

              Description:

              Products overview:
              ZW - LUCB seriesBall valve plug-in vortex flowmeterIs inserted into the pipeline under test center, the measurement of velocity center to calculate the measured flow of large-caliber flowmeter.If install ball valve in pipe inserted into the mouth, can undertake no depletion disassembly of vortex street flowmeter, runtime in smudgy medium to facilitate regular cleaning and maintenance.Instrument parameters can be long-term stability.Using piezoelectric stress sensor, high reliability, can be in - 20 ℃ ~ + 250 ℃ temperature range.There are standard signal simulation and digital pulse signal output, easy with the computer and digital systems, is a more advanced, the ideal flow meter.
              Second, the working principle:
              ZW - LUCB seriesBall valve plug-in vortex street of vortex street flowmeter measuring head (i.e., small vortex flow sensor) is developed by using the theory of "the karman vortex street". In the vortex measurement header table body, the vertical insert a triangular prism spiral body, namely when the tables are in the medium flows through the body, is in the opposite direction in both sides of the triangular prism alternate with the rules of the karman vortex street, the signal frequency of vortex is made of the piezoelectric element detection head, detected on one side of the separation of the vortex frequency proportional to the flow of the medium speed, see formula f = V * St/d / 1-1.27 d
              Type: f - separation vortex frequency, triangular prism side (Hz);
              St, turow ha is a constant;
              Average flow velocity, V, the pipe (m/s);
              D - the width of triangular prism characteristics, (m);
              D - measuring head diameter, (m).
              Through a lot of experimental test, determine the vortex street instrument of measuring head coefficient k. formula is as follows:
              K0 = f/V
              Type: the head meter coefficient K0 - measurement, (1 / m);
              The speed of measure head V points - points, (m/s).
              Based on the relationship of velocity V and the pipe flow, plug-in vortex flow sensor can be determined under the different pipe meter factor KT (1 / m3), average flow velocity and volume to determine the pipe flow.
              Applications:
              ZW - LUCB seriesBall valve plug-in vortex flow meter used in petroleum, chemical, metallurgical, thermal, textile, paper and other industries of superheated steam and saturated steam, compressed air and gas (oxygen, nitrogen, hydrogen, natural gas, coal gas, etc.), water and liquid (such as: water, gasoline, alcohol, benzene, etc.) of the measurement and control.
              Four, the main features:
              1, using micro power consumption of new and high technology, high technology content, stable performance, high precision, long life, technology and components are imported.
              2, simple structure and strong, have no moving parts, high reliability, long running is very reliable
              3, good seismic performance, zero drift, elimination of the influence of external vibration effectively.
              4, the output is the pulse signal is proportional to the flow, no zero drift,
              5, wide measuring range, range than up to now.
              6, the liquid crystal display, at the same time, the instantaneous flow display, accumulative total, display, frequency, percentage, don't have to take turns to switch.
              7, in situ Settings, convenient parameter adjustment, without hand-held com.
              8, small pressure loss, wide dynamic range, low operating cost, comprehensive energy saving.
              9, density, temperature and pressure compensation calculation, compensation formula online inspection.
              10, 0 to 5 khzpinlv output, 4-20 ma output or HATR communications, Modbus protocol communication, can be connected to the industrial automation system.
              11, according to the requirements can separate sensors and instrument, the fission control and remote control.
              Five, the technical parameters:
              1, the nominal diameter (mm) : 12 ~ 2200 plug-in);
              2, nominal pressure (MPa) : 1.6 4.0;
              3, medium temperature (℃) : piezoelectric: - 40-450 ℃ (protocol order);
              4, ontology materials: 1 cr18ni9ti, (other material supply agreement);
              5, accuracy: + / - 1% R, plus or minus 1.5% R, plus or minus 1 fs.Insert: plus or minus 2.5% R, plus or minus 2.5% FS.
              6, the power supply voltage: sensors: DC + 12 v, + 24 v DC;Transmitter: + 24 v DC;Battery type: 3.6 V batteries;
              7, the output signal, square wave pulse type (not including batteries) : a high level 5 v, or low level 1 v or less;Current: 4 ~ 20 ma;
              8, explosion-proof marks: the Ann model: Exd Ⅱ ia CT2 - CT5 flameproof: Exd Ⅱ CT2 - CT5;
              9, protection level: ordinary IP65;
              10, environmental conditions: temperature - 20 ℃ ~ 55 ℃, relative humidity 5% ~ 90%, atmospheric pressure of 86 ~ 106 kpa;
              11, suitable medium: gas, liquid and steam;
              12, transmission distance sensor: zui up to 4 km, two wire transducer (4 ~ 20 ma) : load resistance Ω 750 or less.

              Six, installation requirements:

              1, the sensor should be installed in a horizontal, vertical, inclined (liquid flow from bottom to top) and its size in the same line.Sensors upstream and down 2, should be configured with a certain length of straight pipe, the straight pipe length should comply with the former 15 ~ 20 d, straight pipe after 5 ~ 1 od demands.

              3, installation of liquid sensor near the pipe should be filled with liquid to be tested.

              4, sensor installation should be avoided on the strong mechanical vibration of pipeline.

              5, the inside diameter of straight pipe, as far as possible consistent with the sensor size, if not consistent, slightly larger than the sensor size should be adopted for the pipeline, the error to 3% or less, not more than 5 mm.

              6, sensor installation should be avoided in the strong electromagnetic interference, the space is little, and maintenance is not convenient.

              Seven, installation steps:
              1, the need to install the flow meter of pipeline is directly above (horizontal line with this requirement), cut a slightly smaller than ф 100 holes, remove the burr;
              2, will be the end of form a complete set with the short tube flange at the top of the hole, keep the short tube and vertical tube, welding firmly;
              3, put gasket, insert the flowmeter, flange connection, if there are ball valve, should first put the ball on the short tube connection is good, then open the ball valve, inserted into the meter;
              4.Ensure more than 15 D before and after the flow of 5 D straight pipe to pipe diameter (D).

              Need to pay attention to during the period of eight, debugging, using question:
              1, flowmeter, on-site installation, maintenance, must abide by the "explosion-proof gas do not open" warnings, and in the open before turn off the power supply.
              2, vortex flow meter used in outdoor, suggestion and side shields.
              3, shall not be arbitrarily fixed part loosen the flowmeter.The protection of the pressure sensor.Users in the use of traffic time, should pay attention to the flow pressure overload value of pressure sensor is rated working pressure of 1.5 times (i.e., medium to high pressure of 1.5 times).Selection should be within the prescribed flow range, prevent overspeed operation, in order to obtain the ideal accuracy and ensure the normal service life.(due to pressure test, purging pipes or exhaust overdrive, and turbine operation in the reverse flow meter can cause damage)
              4 when put into operation, the vortex street flowmeter, should slowly open valve, prevent damage of instantaneous flow and the turbine.Add lubricant should be according to the sign, the number of refueling depends on temperament clean degree, usually 2 ~ 3 times a year.
              5, vortex street flowmeter runtime or alternate internal related parameters are not allowed to open the rear cover, otherwise will affect the normal operation of the meter.

              Nine, note:

              1. The special flange and straight pipe welding can't with the sensor.

              2. When installation should make the flow of sensor mark the direction of flow and the pipe.

              3. Before the installation of sensor and the flange must be put away in sealing ring grooves.The location of the pressure and temperature measurement point, pressure downstream of the sensor in 3 ~ 5 dn, temperature measuring points in the downstream of 5 ~ 8 dn.

              4. When measuring high temperature medium, do not use insulation wrapped around the sensor link rod.

              5. Shielded cable to connect the sensor, should as far as possible away from the interference of strong electromagnetic field.Absolutely not allowed with high voltage cable laying, shielded cable to shorten as far as possible, and shall not be volume, in order to reduce stray inductance, zui big length should be not more than 200 meters.

              6. Before installation of sensors, pipeline cleaning must be conducted.Flow after rinse tube impurities, avoid clogging sensor.Measuring liquid pipe must be full of measured liquid, prevent the interference of bubbles.

              7, measuring gas pipelines to prevent the interference of reservoir fluid.Replace the probe body under the high temperature and high pressure, it must be safe operation, high temperature protection.After cooling step-down replaceable probe at the bottom of the safety conditions.

              Ten, parameter table:

              Nominal menstruation (mm)

              250~1500

              Instrument material

              1Cr18Ni 9Ti

              Nominal pressure (Mpa)

              PN1.6Mpa;PN2.5Mpa

              Measured medium temperature (℃)

              -40~+ 250℃

              Environmental conditions

              The temperature -10~+ 55℃, relative humidity5% ~90%, the atmospheric pressure86~106Kpa

              Precision grade

              The value forPlus or minus 2.5%

              Range than

              ";1:15

              The resistance loss coefficient

              Cd<2.6

              The output signal

              Sensors: pulse frequency signal0.1 ~ 3000Hz Low level≤1V High level≥6V
              Transmitter: two wire system4 ~ 20mADCCurrent signal

              Power supply

              Sensors:,+24VDC
              Transmitter:+24VDC
              Display type: instrument cabin3.2VThe lithium battery

              The signal transmission line

              KVVP3×0.3(three-wire system),2 x 0.3(Two wire)

              Transmission distance

              ≤500m

              Line interface

              Internal threadM20×1.5

              Explosion-proof grade

              ExdIIBT6

              Protection grade

              IP65

              Allow the vibration acceleration

              1.0g

              Eleven, flow range:

              code

              Nominal diameter

              (mm)

              Flow range (m3 / h)

              liquid The body of the

              gas The body of the

              steamed steam

              ZW-LUCB

              250

              100~1000

              1000~8000

              930~8000

              ZW-LUCB

              300

              150~1500

              1500~11500

              1330~11440

              ZW-LUCB

              350

              200~2000

              2000~15600

              1800~15600

              ZW-LUCB

              400

              250~2500

              2500~20000

              2400~20000

              ZW-LUCB

              500

              400~4000

              4000~30000

              3700~31800

              ZW-LUCB

              600

              500~5000

              5000~45000

              5300~45800

              ZW-LUCB

              700

              700~7000

              7000~60000

              7300~62300

              ZW-LUCB

              800

              900~9000

              9000~80000

              9500~81400

              ZW-LUCB

              1000

              1400~14000

              14000~120000

              14800~127200

              Twelve, selection of coding:

              Code name

              CAL

              With ball valve plug-in vortex street flowmeter (wei measurement and control)

              ZW-LUCB 020

              200mm

              ZW-LUCB 025

              250mm

              ZW-LUCB 030

              300mm

              ZW-LUCB 035

              350mm

              ZW-LUCB 040

              400mm

              ZW-LUCB 045

              450mm

              ZW-LUCB 050

              500mm

              --------

              --------

              ZW-LUCB 0200

              2000mm

              Code name

              function1

              N

              No temperature pressure compensation

              Y

              With temperature compensation

              Code name

              Output type

              F1

              4-20mAOutput (two-wire system)

              F2

              4-20mAOutput (three-wire system)

              F3

              RS485Communication interface

              Code name

              Measured medium

              J1

              liquid

              J2

              gas

              J3

              steam

              Code name

              function2

              E

              2.5level

              T1

              The normal temperature

              T2

              The high temperature

              T3

              steam

              P1

              1.6MPa

              P2

              2.5MPa

              P3

              4.0MPa

              D1

              internal3.6VThe power supply

              D2

              DC24VThe power supply

              B1

              Stainless steel

              B2

              Carbon steel

              13, order selection selection guidelines:

              Name and model number of 1, 1), (2) the diameter, flow range, (3) whether or not to bring the attached so that we can correct selection for you, (4) using pressure, (5) the use of medium temperature.

              2, if has been selected by design units in the way of vortex street flowmeter types, please press type vortex flowmeter directly order from our sales department.

              3, when using occasions is very important, or the environment is complex, please try to provide the design drawings and detailed parameters, by wei experts in our audit checks for you.

              After-sales service commitment:

              1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

              2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

              3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

              4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.

              Browse: